Home > Error Code > Smpp Protocol Error Codes

Smpp Protocol Error Codes

Contents

ESME_RINVMSGLEN 1 Invalid Message Length (sm_length parameter) ESME_RINVCMDLEN 2 Invalid Command Length (command_length in SMPP PDU) ESME_RINVCMDID 3 Invalid Command ID (command_id in SMPP PDU) ESME_RINVBNDSTS 4 Incorrect BIND status for What is an SMS Service Provider? If not known set to Unknown. Error Codes If you receive an SMPP error, you can use this information to help you determine the source of the error. have a peek here

Please try the request again. The remaining two octets specify the actual network error code appropriate to the network type. WindowsToolkits.com Internet Resource for Windows toolkit software. smpp-submit-protocol-id Submit Integer 0 GSM: Set according to GSM 03.40 [GSM 03.40], ANSI-136 (TDMA): For mobile terminated messages, this field is not used and is therefore ignored by the SMSC.

Smsc Error Code List

Currently SMPP accounts need to be activated by World-Text support who you should contact at [email protected] SMPP Interface API SMPP Interface Specification SMPP interface specification technical manual. Remember to do appropriate conversion before checking on results returned by SMSC through library functions.

The information or statements in this document concerning the specification or performance of World Text software or hardware systems shall not constitute any binding promise or warranty. The system returned: (22) Invalid argument The remote host or network may be down. Key Used at Possible Values Default Value Description smpp-version Bind 51 – 3.352 – 3.4 51 This parameter is used to indicate the version of the SMPP protocol. Smpp Delivery Status Codes Error Number Error Name Error Description 0x00000000 ESME_ROK No Error 0x00000001 ESME_RINVMSGLEN Message too long 0x00000002 ESME_RINVCMDLEN Command length is invalid 0x00000003 ESME_RINVCMDID Command ID is invalid or not supported 0x00000004

Enquire Links to our server should be sent no more than once in every 60 second period. Submit_sm Response Codes For your destination address the TON and NPI should both be set to 1 SMPP Command ID Values ID Value Description 0x80000000 ESME_NACK Negative Acknowledgement 0x00000001 ESME_BNDRCV Bind to SMSC Kernel smpp-bind-addr-ton Bind 0 – Unknown1 – International2 – National3 – Network Specific4 – Subscriber Number5 – Alphanumeric6 - Abbreviated 0 Indicates Type of Number of the ESME address. Suitable for use with all standard SMPP applications as based on SMPP v3.3 / v3.4 protocols.

All other values reserved. Smpp Bind Failed The information in this document is subject to change without notice. Examples include “VMS” (voice mail system) and “OTA” (over-the-air activation system). Value Meaning 0x400 Insufficient credit remaining on pre-pay account or credit limit has been reached (invoiced accounts).

Submit_sm Response Codes

smpp-submit-source-addr Submit Specifies the address of SME which originated this message. https://docs.openmarket.com/ The following list is an overview of codes SMPP providers will return in the "command_status" field in case of an error. Smsc Error Code List SMPP is not available to trial accounts, after you have made your first purchase of SMS credits please contact us to have SMPP enabled. Esme Receiver Reject Message Error SMPP Server Restarts From time to time the SMPP server is restarted to allow for upgrades and configuration changes, although we try to keep these to a minimum, they are required.

smpp-submit-source-addr-ton Submit 0 – Unknown1 – International2 – National3 – Network Specific4 – Subscriber Number5 – Alphanumeric6 - Abbreviated 0 Source Address TON. http://phabletkeyboards.com/error-code/smpp-error-codes-8.php smpp-submit-esm-class Submit Integer 0 The esm_class parameter is used to indicate special message attributes associated with the short message. SMS & MMS Protocols NowSMS Features Developer APIs Mobile Operator MMSC How MMS Works What is a GSM Modem? ESME_RMISSINGOPTPARAM 0x000000C3 Expected Optional Parameter missing ESME_RINVOPTPARAMVAL 0x000000C4 Invalid Optional Parameter Value Reserved 0x000000C5-0x000000FD Reserved ESME_RDELIVERYFAILURE 0x000000FE Delivery Failure (used for data_sm_resp) ESME_RUNKNOWNERR 0x000000FF Unknown Error Reserved for SMPP extension 0x00000100-0x000003FF Esme Receiver Temporary App Error Code

Select Manage System > Notification Settings > SMS Channel. Please try the request again. Generated Fri, 28 Oct 2016 07:14:52 GMT by s_fl369 (squid/3.5.20) Check This Out SMPP Keys Use these SMPP keys when you configure WatchGuard Administrator.

One such SDK is the SMPP Developers Toolkit and is available from Logica CMG. Smpp Bind Failed Code 13 Numbering Plan Indicator for destination. For IS-95 mobile originated messages, the SMSC should set this value to NULL.

Multi-binds If you require multi-binds, by default this is not enabled.

SMPP activation normally takes no longer than 24 hours excluding weekends. smpp-submit-source-addr-npi Submit 0 – Unknown1 – ISDN3 – Data4 – Telex6 – Land Mobile8 – National9 – Private10 – ERMES14 – Internet18 – WAP Client Id 0 Source Address NPI. Shortcut Menu Sponsor Submit a program Contact us SMSSolutions.net Skip Main Navigation Home Freeware Hardware GSM/GPRS Modems GSM/GPRS Modules CDMA Modems CDMA Modules Software SMS/MMS Applications SMS/MMS Gateways SMS Components WAP Smpp Delivery Receipt Error Codes Custom Status Values In addition to the standard SMPP status values returned in SMPP Message Header, the following are also valid vendor-specific values.

Configuring SMPP To configure SMPP parameters, add an additional SMS configuration. smpp-submit-data-charset Submit String ISO8859-1 Character set to use in conjunction with Data Coding when converting from Unicode to output format. If you require to use a different source address then please see the information on our web site to request additional source addresses. this contact form Connection Settings Host and Port Information: Host/Portname Primary Host * Backup Host Hostname smpp1.world-text.com smpp2.world-text.com TX Port 8010 8010 RX Port 8010 8010 TRX Port 8010 8010 Please check back regularly

Further information on this toolkit is available from Logica CMG Other toolkits and SMPP capable applications are available from 3rd party vendors. If they do not disconnect, the connections are forceably closed, once disconnected your application should automatically rebind to the server, the frequency of rebinds should not be more than once every IS-95 (CDMA): For mobile terminated messages, this field is not used and is therefore ignored by the SMSC. Your cache administrator is webmaster.